MSP340 Pressure Transducer
PERFORMANCE SPECIFICATIONS
Supply Voltage: 5.0V, Ambient Temperature: 25°C (unless otherwise specified)
PARAMETERS
Zero Offset Tolerance
Span Tolerance
Accuracy (combined non linearity, hysteresis, and repeatability)
Long Term Stability (1 year)
MIN
-2.0
-2.0
-1.0
-0.25
TYP
MAX
2.0
2.0
1.0
0.25
UNITS
%F.S.
%F.S.
%F.S.
%F.S.
NOTES
1
1
2
Isolation, Body to Any Lead (@250Vdc)
50
M
Temperature Error – Zero
Temperature Error – Span
Compensated Temperature
Operating Temperature
Storage Temperature
Pressure Cycles (Zero to Full Scale)
Proof Pressure
Burst Pressure
Load Resistance (RL, mV Output)
Load Resistance (RL, V Output)
-2.0
-2.0
0
-20
-40
10
2X
5X
RL > 1
RL > 5
2.0
2.0
55
+85
+85
%F.S.
%F.S.
°C
°C
°C
Million
Rated
Rated
M
K
Bandwidth
Shock
Vibration
For custom configurations, consult factory.
Notes
1. Over compensated temperature range.
2. Best fit straight line.
DC to 1KHz (typical)
50g, 11 msec Half Sine Shock per MIL-STD-202G, Method 213B,
Condition A
±20g, MIL-STD-810C, Procedure 514.2-2, Curve L
MSP340
www.meas-spec.com
2/5
July 2012